Troubleshooting
Troubleshoot the active REMMS path. Do not switch a live board back to an old MMS communication layer to work around a failure.
Altirra Does Not Boot The Board
- Confirm the Mutineer ATR is mounted as
D1:. - Confirm SpartaDOS X is mounted as the cartridge.
- Confirm BASIC is enabled.
- Confirm fast boot is enabled.
- If you only want to inspect the ATR, boot a utility disk as
D1:and mount Mutineer as a secondary disk so it does not auto-start.
Expected startup:
AUTOEXEC.BAT -> RHND850.COM -> REMMS.COM -> BASIC -> WFC
No Listener Or No Connection
- Confirm the Atari 850 device is enabled.
- Confirm 850 emulation is Full.
- Confirm the modem is a child device of the 850.
- Confirm the modem is inbound/listen on
127.0.0.1:6507. - Confirm no other Altirra instance owns port
6507. - Keep Telnet LF translation off.
- Leave CIO
R:patch off.
The caller should see:
CONNECTED PRESS [RETURN]
If the caller sees WFC dashboard text before that prompt, the BBS is leaking local dashboard output to the modem and should not be used as a release image.
Return Does Not Work
Use a normal CR or CR/LF Return from the terminal client. In PuTTY, use Telnet, set local echo to Auto or Force off, and leave local line editing off.
If the A command says HIT <RETURN> and then ignores Return, the runtime is
using an older CORE/REMMS combination. Use a current release ATR.
First User Is Not Sysop
The first completed registration becomes user number 1 and access level 9.
If a test user was created first, restore your clean ATR backup or use offline
maintenance to repair the user/access files.
Files involved:
D1:>DATA>USERS.DATD1:>DATA>USERS.IDXD1:>DATA>NEXTUSER.DATD1:>DATA>ACL.CFG
Cannot Reach A Module
- Confirm the main menu prompt is visible.
- Use
?to redraw the main menu. - Use
Mfor message bases,Ffor file areas, andDfor doors. - Use
Xinside message, file, and door menus to return to CORE. - If the board disconnects, reconnect and confirm WFC answers normally.
Online modules must preserve REMMS session state. If a custom module loses the
caller, review its session restore, ROPEN,0, route, and return path.
Door Is Missing
Missing doors print:
DOOR UNAVAILABLE.
Check:
- the caller's access level meets the door catalog level;
- the door path in the offline
DOORS.CFGsource ends in>; D1:>DATA>DOORCAT.DATwas rebuilt after catalog edits;- the 16MB Mutineer ATR contains the expected
D1:>DOORS>directory; - the runtime catalog target agrees with the bundled
D1:path.
Message Or File Area Looks Wrong
- Confirm message bases use
MESG?.MET,MESG?.DAT, andMESG?.IDX. - Confirm file areas use
FILE?.MET,FILE?.DAT, andFILE?.IDX. - Confirm the metadata paths point to existing files.
- Use offline maintenance tools for rebuild/compact work.
- Keep a backup before changing live data files.
Dropped Calls
REMMS should detect carrier loss and return to WFC. If a custom module hangs after a caller disconnects, it is probably waiting for input without polling REMMS status.
At input boundaries, caller-facing modules should call RSTAT, RTGET, or
REVENT, handle structured results at or above 256, and return fatal or
carrier-loss states to WFC.
Backups
Keep a clean release ATR and a separate live ATR. Back up the live ATR before:
- complete initialization;
- editing user files;
- editing message or file metadata;
- adding door catalog rows;
- replacing text assets;